3.2.3 Grounding (NSW200-28P)

Grounding is a safety measure to have unused electricity return to the ground. It prevents damage to
the NSW and protects you from electrocution.
Remove the M4 ground screw from the NSW's rear panel.
1
Secure a green/yellow ground cable (16AWG or smaller) to the NSW's rear panel using the M4 ground
2
screw.
Attach the other end of the cable to the ground, either to the same ground electrode as the rack you
3
installed the device on or to the main grounding electrode of the building.
Follow your country's regulations and safety instructions to electrically ground the device properly.
If you are uncertain that suitable grounding is available, contact the appropriate electrical inspection
authority or an electrician.
Note: Qualified service personnel must confirm that the building's protective earthing
terminal is a valid terminal.
Warning! Connect the ground cable before you connect any other
cable or wiring.

3.3 LEDs

After you connect the power to the NSW, view the LEDs to ensure proper functioning of the NSW and as
an aid in troubleshooting.
Note: Please refer to Nebula Device Startup LED Guide, for more information about the
system and locator LEDs when they light up at the same time.
The following table is for NSW100 Series.
Table 3 LED Descriptions for NSW100 Series
LED
COLOR
PWR
Green
SYS
Green
Chapter 3 Hardware Panels
STATUS
DESCRIPTION
On
The system is turned on.
Off
The system is off or has failed.
On
The system is on and functioning properly. The NSW can connect to the
Nebula Control Center.
Blinking
The system is rebooting and performing self-diagnostic tests.
If the system LED is blinking green with the alarm LED blinking red, it means the
NSW cannot connect to the Nebula Control Center.
If the system LED is blinking green while the Locator LED is a steady blue, the
NSW is not registered to the Nebula Control Center.
Off
The power is off or the system is not ready/malfunctioning.