2.3 Mounting the NSW on a Rack

The NSW can be mounted on an EIA standard size, 19-inch rack or in a wiring closet with other
equipment.
Follow the steps below to mount your NSW on a standard EIA rack using a rack-mounting kit.

2.3.1 Rack-mounted Installation Requirements

• Two mounting brackets.
• Eight M3 flat head screws and a #2 Philips screwdriver.
• Four M5 flat head screws and a #2 Philips screwdriver.
Failure to use the proper screws may damage the unit.
2.3.1.1 Precautions
• Make sure the rack will safely support the combined weight of all the equipment it contains.
• Make sure the position of the NSW does not make the rack unstable or top-heavy. Take all necessary
precautions to anchor the rack securely before installing the unit.

2.3.2 Attaching the Mounting Brackets to the NSW

Position a mounting bracket on one side of the NSW, lining up the four screw holes on the bracket with
1
the screw holes on the side of the NSW.
Figure 6 Attaching the Mounting Brackets (NSW100-10P and NSW100-10)
Chapter 2 Hardware Installation and Connection
NSW Series User's Guide
14