10 Settings
Parameter
Parameter
number
6200
Save sensors
6212
Check no. heat
source 1
6213
Check no. heat
source 2
6215
Check no. storage
tank
6217
Check no. heating
circuits
6230
Info 1 OEM
6231
Info 2 OEM
Tab.53
Configuration menu: parameters for extension modules 1, 2 and 3
Parameter
Extension module 1
Extension module 2
6020 : Funct value 2
6021 : Function
H2 module 3
extension module 2
6024 : Funct input
6026 : Funct input
EX21 module 1
EX21 module 2
6030 : Relay output
6033 : Relay output
QX21 module 1
QX21 module 2
6031 : Relay output
6034 : Relay output
QX22 module 1
QX22 module 2
6032 : Relay output
6035 : Relay output
QX23 module 1
QX23 module 2
6040 : Sensor input
6042 : Sensor input
BX21 module 1
BX21 module 2
6041 : Sensor input
6043 : Sensor input
BX22 module 1
BX22 module 2
6046 : Function input
6054 : Function input
H2 module 1
H2 module 2
6047 : Contact type
6055 : Contact type
H2 module 1
H2 module 2
6049 : Voltage value 1
6057 : Voltage value 1
H2 module 1
H2 module 2
88
POWER HT +
Description
Records the sensors used in the appliance.
Information on the manufacturer
Extension module 3
6022 : Function
extension module 3
6028 : Funct input
EX21 module 3
6036 : Relay output
QX21 module 3
6037 : Relay output
QX22 module 3
6038 : Relay output
QX23 module 3
6044 : Sensor input
BX21 module 3
6045 : Sensor input
BX22 module 3
6062 : Function input
H2 module 3
6063 : Contact type
H2 module 3
6065 : Voltage value 1
H2 module 3
Description
None
Multifunctional : The functions
that can be assigned to the in­
puts/outputs.
Temps / mode CH1 : Settings
corresponding to the operator
chapter on "Heating Circuit 1".
Temps / mode CH2 : Settings
corresponding to the operator
chapter on "Heating Circuit 2".
Temps / mode CH3 : Settings
corresponding to the operator
chapter on "Heating Circuit 3".
Return temp controller : Not
used
Solar HW : Settings correspond­
ing to the operator chapter on
"Thermal Solar".
Primary contr/system pump : Not
used
None
Limit thermostat CH
See
QX1 relay outlet
See
QX1 relay outlet
See
QX1 relay outlet
See
BX2 sensor inlet
See
BX2 sensor inlet
See
H5 inlet function
NC
NO
Definition of parameters for collec­
tor specifications
Factory set­
ting
no
Factory setting
Without
None
without
without
without
without
without
without
NO
0
7702630 - v02 - 11082018