Refitting The Burner - Baxi POWER HT+ Series Installation, User And Service Manual

Hide thumbs Also See for POWER HT+ Series:
Table of Contents

Advertisement

11 Maintenance
Fig.168
1
5 N.m
2
23 N.m
Fig.169
2
5 N.m
MW-2000816-01
116
POWER HT +
11.2.6
POWER HT+ 1.130 and POWER HT+ 1.150
Important
Replace the sealing gaskets to ensure perfect leak-tightness is
maintained.
1. Refit the assembly comprising the fan, Venturi, burner and gas valve.
2. Refit the nuts holding the burner in place on the exchanger.
Important
Observe the tightening torque.
3. Refit the screws securing the gas inlet tube elbow.
Important
Observe the tightening torque.
4. Reconnect the 2 connectors to the gas valve.
5. Reconnect the 2 wires between the safety thermostat on the
combustion chamber door and the pin under the ignition electrode.
6. Reconnect the ignition electrode and the flame detection sensor.
7. Reconnect the power supply and command cables on the fan.
MW-2000803-01
POWER HT+ 1.200 and POWER HT+ 1.250
Important
Replace the sealing gaskets to ensure perfect leak-tightness is
maintained.
1. Refit the assembly comprising the fan, Venturi, burner and gas valve.
2. Refit the nuts holding the burner in place on the exchanger.
Important
Observe the tightening torque.
3. Refit the screws securing the gas inlet tube elbow.
Important
Observe the tightening torque.
3
23 N.m

Refitting the burner

7702630 - v02 - 11082018

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents