Incident: the machine does not charge:

With or without the following fault codes: BAT. TEMPERATURE or BATTERY TEMP SENSOR
Charge lamp on, fault
lamp flashing and
charger fan not
running
On TEP96 test:
OTHER FUNCTIONS
♦ Reading variables
♦ Memory battery
♦ Check in disjunct
⇓ All variables
♦ Large Amperemeter
♦ Large voltmeter
⇑ Large Speedometer
* VARIABLES (PAGE 3) *
Tempera. batt =
Tempera. uce
Tempera. motor =
If after 2 hrs the battery temperature is not under 55°, check the battery temperature functions and
Reproductions or translations, even parrtial, are forbidden without the written consent of Peugeot Motocycles
TROUBLESHOOTING LOGIC DIAGRAM
Machine connected
Charge lamp on and
charger fan not
documentation
voltage over
55 °C
=
25°C
?°C
change it if necessary (sensor fault, or sensor information error).
to 220 V mains
running
Change the
charger. See
workshop
Voltage under 8 V apply
procedure: charging after
prolonged immobilisation
(see appropriate chapter)
Battery
No fault but battery temperature safety
55°c
in this case leave the machine connected
Charge lamp off and
charger fan not
running
Test
200 A
fuse
Check
battery
voltage
Voltage over 12V,
change the charger (see
workshop
documentation)
triggered (room too hot, external
temperature too high)
and the charge to finish
Test the
220-230 V
mains and
charging
cable