BATTERY REPLACEMENT PROCEDURE (3 cells)

Important point:

This operation may only be carried out after battery replacement consent from PEUGEOT MOTOCYCLES
If one or two of the cells is to be replaced, discharge the remaining cell(s) separately using the discharge
bench (see discharge bench user manual)
1. To change the battery, see the scoot'elect workshop manual
2. After replacement, connect the TEP 96 and turn on the ignition
3. Initialise parameters

Method for TEP 96 version 1.5. before July 1998:

Select the "Exchange battery" line from the main
menu and confirm
OTHER FUNCTIONS
♦ Reading variables
♦ Exchange ecu
⇑ Exchange battery
Reproductions or translations, even parrtial, are forbidden without the written consent of Peugeot Motocycles
BATTERY REPLACEMENT PROCEDURE

Method for TEP 96 version 2.0. after July 1998:

Select the "SPECIAL FUNCTIONS" line from the
main menu and confirm
OTHER FUNCTIONS
♦ Ιdentity UCE
♦ Ιdentity TEP
⇑ SPECIAL FUNCTIONS.
To access the special functions, press on the 2
buttons on the bottom of the TEP 96 for a
minimum of 3 seconds.
TO OPENING SPECIALS
REQUEST AGREEMENT
PEUGEOT MOTOCYCLES
Then confirm on the "Exchange battery" line.
SPECIAL FUNCTIONS
Exchange uce
Exchange battery
FUNCTIONS