4. A "Parameters to initialize ? NO/YES" screen is displayed, press YES
5. Another screen is displayed asking you to confirm writing in the ECU, press YES
6. Disconnect the TEP 96 and switch off the ignition for a minimum of 20 seconds to confirm parameter
transfer
7. Turn on the ignition and enter the machine code, the power gauge is at 0%, the charge and maintenance
lights flash showing that the parameters have been initialised
8. At this point, battery commissioning must be carried out (see battery commissioning and maintenance
procedure chapter)
Reproductions or translations, even parrtial, are forbidden without the written consent of Peugeot Motocycles
BATTERY REPLACEMENT PROCEDURE
* EXCHANGE BATTERY *
Parameters to
Initialize ?
* EXCHANGE BATTERY *
Are you replace
It by a new
NO : •
YES : •
NO : •
YES : •