Mitsubishi Electric CR750-D Series Instruction Manual page 76

Industrial robot, the sample screen of got2000, for got direct connection extended function, got script version
Hide thumbs Also See for CR750-D Series:
Table of Contents

Advertisement

(3) See below for the [Robot Error Screen]. For details of the operation buttons, see [Table
4-18: Details and roles of "Robot Error Screen" Operation Buttons].
【Screen Specifications】
Screen to monitor the robot errors in chronological order
(1) Error Display・・・Displays the description of an ongoing error
* Upper column: error description
Middle column: cause
Lower column: restoration
(2) Troubleshooting・・・Jump to "Troubleshooting" in the [Robot Manual Menu]
(3) History・・・Jumps to the history screen
(4) ▲/▼ Buttons・・・Switches the error screens ▲ for the previous error and▼ for the next error
(5) Program Name・・・Displays the name of program with an error
(6) Line No.・・・Displays the line number of the program with an error
(7) Error Line No. ・・・Displays the number of ongoing error
(8) Error Reset Button・・・Resets the error with ERR.RESET
(9) Common Buttons・・・Jump to each screen
* "STOP" stop a running program (Servo remains ON)
69

Hide quick links: