(4) See below for the [Maintenance Forecast 1/2] screen. For details of the operation buttons,
see [Table 4-16: Details and Roles of "Maintenance Forecast" Operation Buttons].
【Screen Specifications】
Screen to monitor the robot grease
(1) Back・・・Switches the dedicated signal monitor screens [Dedicated Signal Monitor 1/2]
→[Dedicated Signal Monitor 2/2]
(2) Next・・・Switches the dedicated signal monitor screens [Dedicated Signal Monitor 1/2]
→[Dedicated Signal Monitor 2/2]
(3) Grease・・・Displays the grease useable time for each axis (J1, J2, J3, J4, J5, and J6)
(4) Reset・・・Displays 6000 hours for a reset (by each axis)
* Grease is useable up to 6000 hours
(5) Display of Running State・・・Lights the lamp according to the robot running status
* Automatic Operation in Progress (green) Servo Power (green) Error (red)
Current operation speed value (%)
(7) UP/DOWN・・・Changes the operation speed in the OVRD DISPLAY UP (speed-up),
DN (speed-down)
(7) Common Buttons・・・Jump to each screen
* "STOP" stop a running program (Servo remains ON)
(currently unavailable)