At+Csns Single Numbering Scheme - Siemens TC35i User Manual

Terminal hardware interface
Hide thumbs Also See for TC35i:
Table of Contents

Advertisement

TC35i AT Command Set
7.25 AT+CSNS
7.25

AT+CSNS Single Numbering Scheme

Syntax
Test Command
AT+CSNS=?
Response(s)
+CSNS: (list of supported
OK
Read Command
AT+CSNS?
Response(s)
+CSNS:
<mode>
OK
Write Command
AT+CSNS= [
]
<mode>
Response(s)
OK
PIN
ASC0
MUX1
!
%
%
Reference(s)
GSM 07.07
Command Description
The
command enables the ME to accept incoming calls when no bearer capability information is pro-
AT+CSNS
vided with the call, e.g. single numbering scheme calls or calls originitating from analog devices.
Parameter Description
(num)
<mode>
(D)
[0]
2
4
TC35i_ATC_V02.07
Confidential / Released
s)
<mode>
MUX2
MUX3
%
%
Voice: Each call received without bearer element is assumed to be speech
Fax: Each call received without bearer element is assumed to be an incoming
fax.
Data: Each call received without bearer element is assumed to be a data call.
Please take into account that the bearer service parameters set with
apply to all data calls including those received without bearer capability.
Page 178 of 439
s
m
obile
AT+CBST
1/30/04

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tc35i terminal

Table of Contents