D-Link DES-3326SR User Manual page 248

Layer 3 switch
Hide thumbs Also See for DES-3326SR:
Table of Contents

Advertisement

DES-3326SR Layer 3 Fast Ethernet Switch User's Guide
Figure 6 - 70. IGMP Interface Configuration − Edit
This dialog box allows the configuration of IGMP for each IP
interface configured on the switch. IGMP can be configured as
Version 1 or 2 by toggling the Version field using the pull-down
menu. The length of time between queries can be varied by
entering a value between 1 and 65,500 seconds in the Query
Interval field.
The maximum length of time between the
receipt of a query and the sending of an IGMP response report
can be varied by entering a value in the Max Response Time
field.
The Robustness Variable field allows IGMP to be 'tuned' for
sub-networks that are expected to lose a lot of packets. A high
value (max. 255) for the robustness variable will help
compensate for 'lossy' sub-networks. A low value (min. 2)
should be used for less 'lossy' sub-networks.