Nikon VBA23001 Repair Manual page 108

Table of Contents

Advertisement

・Mount the view field frame 2 (#264) and the penta prism (#4).
Mount the view field frame 2 (#264) and the penta prism (#4).
・Mount the protection sheet (#269) and the penta prism retainer (#267).
Mount the protection sheet (#269) and the penta prism retainer (#267).
・Attach the double-stick tape (#780) to the penta prism retainer (#267).
Attach the double-stick tape (#780) to the penta prism retainer (#267).
・Hook and attach the insulation sheet (#270) to the penta prism retainer (#267).
Hook and attach the insulation sheet (#270) to the penta prism retainer (#267).
(Be careful of the attaching direction of [#270].)
・Attach the double-stick tape (#781).
Attach the double-stick tape (#781).
Double-stick tape (#781)
Insulation sheet (#270)
Double-stick tape (#780)
Penta prism retainer (#267)
Protection sheet (#269)
- A26 ・ D90 -
INC
VBA23001-R.3762.A
Penta prism (#4)
View field frame 2 (#264)