< Measurement of Consumption current value >
When this camera is used for measuring the consumption current value, connect the battery tool (J61213), and
turn the change-SW to OFF. Then make measurements based on the following.
7.8V 0.3Ω
《Inspection standards》
Main SW / OFF
All operational buttons are NOT pushed.
Main SW / ON (Half-release timer OFF)
Main SW / ON (Half-release timer ON)
Main SW / ON (Illumination ON)
Main SW / ON (TFT ON)
Main SW / ON (Operating consumption current)
Caution:
When the consumption current value is measured, backup battery must be fully charged.
Turn change-SW to OFF.
Test item
- A110 ・ D90 -
Standard
250μA or less
ref. above.
AF50/1.4D、EV12
250μA or less
200mA or less
250mA or less
   
400mA or less
4A or less
INC
VBA23001-R.3762.A
Test condition