Calling up parameter level 2

Parameters are split into the following groups:
"General"
"Boiler"
"DHW"
"Solar"
"Ventilation"
"Heating circuit 1/2/3"
"All parameters"
In this group, all parameters are shown in ascend-
ing order (the parameters for the "Solar" and
"Ventilation" groups are only shown if a solar con-
trol module, type SM1 and/or ventilation control
module, type LM1 are connected).
Heating systems with one heating circuit without
mixer and one or two heating circuits with mixer:
In the following, the heating circuit without mixer is
designated "Heating circuit 1" and the heating cir-
cuits with mixer as "Heating circuit 2" or "Heating
circuit 3".
If the heating circuits have been designated individu-
ally, the chosen designation appears.
Tap the following buttons:
01. "Menu" or "
"
02. "Service"
03. Enter the password "viservice".
04. "System configuration"
05. "Parameter level 2"
06. Enter the password "viexpert".
07. Select group.
08. Select parameter.
09. "Change" or
10.
/ or
/
for the required value in line with the
tables below.
11. OK or "
" to accept the selected value.
Fig. 42
Display of parameter HO2B
Parameter
A
Description of parameter setting
B
C
Number of parameter
Value of parameter
D
Parameter level 2
63