04. Remove the 4 screws from the fitting assembly.
05. Raise the boiler so that it is separated from the
connections. Remove the boiler from the wall.
06. Before fitting the boiler:
Insert new O-rings.
Lubricate the O-rings with the valve grease sup-
plied.
07. Insert new flat gasket for the gas shut-off valve.
08.
Danger
Take care not to injure your hands.
Do not take hold of the boiler at the bottom
at the back.
Fitting the boiler:
Position the boiler centrally in front of the wall
mounting bracket. Use the outer ends of the wall
mounting bracket to line up the boiler.
Lower the boiler vertically into position.
The supporting surface of the boiler must rest on
the fitting assembly.
110
09. Insert 4 screws into the fitting assembly from
below.
Torque 3 Nm.
Do not tighten the screws with a cordless screw-
driver.
10. Tighten the union nut on the gas pipe.
Torque 30 Nm.
Danger
Escaping gas leads to a risk of explosion.
Check the fitting for gas tightness.

Hide quick links: