Checking The Burner Gasket And Burner Gauze Assembly - Viessmann VITODENS 200-W Installation And Service Instructions Manual

Type b2hb, b2kb, 1.8 to 35 kw wall mounted gas condensing boiler with vitotronic 200, weather-compensated natural gas and lpg version
Table of Contents

Advertisement

Checking the burner gasket and burner gauze assembly

Check burner gasket
A
and burner gauze assembly
for possible damage and replace if required.
E
B
Fig. 29
1. Remove electrodes
B
2. Undo 2 retaining clips
D
and then remove thermal insulation ring
3. Undo 2 Torx screws and remove burner gauze
assembly
with gasket
E
4. Insert new burner gauze assembly
gasket
and secure.
F
Torque: 5.0 Nm.
F
E
2x
C
.
on thermal insulation ring
C
D
.
.
F
E
with new
Commissioning, inspection, maintenance
D
A
2x
5. Fit thermal insulation ring
6. Fit electrodes
B
Torque: 4.5 Nm.
.
D
.
43