Internal H2 Extension - Viessmann VITODENS 200-W Installation And Service Instructions Manual

Type b2hb, b2kb, 1.8 to 35 kw wall mounted gas condensing boiler with vitotronic 200, weather-compensated natural gas and lpg version
Table of Contents

Advertisement

Internal extensions (accessories)

Internal H2 extension

Fig. 70
The internal extension is integrated into the control unit
enclosure. The following alternative functions can be
connected to relay output
via parameter "53" in the "General" group:
Central fault message (parameter "53:0")
DHW circulation pump (parameter "53:1") (only for
weather-compensated operation)
Connect DHW circulation pumps with standalone
functions directly to the 230 V
(cont.)
sK
. The function is assigned
supply.
Heating circuit pump for heating circuit without mixer
(parameter "53:2")
Circulation pump for cylinder heating (parameter
"53:3")
An extractor fan can be switched off via connection
when the burner starts.
aBJ
Function description
143