Heating Circuit 1, Heating Circuit 2, Heating Circuit 3 - Viessmann VITODENS 200-W Installation And Service Instructions Manual

Type b2hb, b2kb, 1.8 to 35 kw wall mounted gas condensing boiler with vitotronic 200, weather-compensated natural gas and lpg version
Table of Contents

Advertisement

Heating circuit 1, heating circuit 2, heating circuit 3

Note
Parameter values in bold are factory settings.
"Heating limit: Economy function outside temperature"
Setting
5 see service instructions
Without
... see service instructions
Parameter
With economy function outside tem-
A5:...
perature: Heating circuit pump
"OFF"
1
OT
RT
>
set
2
OT
RT
>
set
3
OT
RT
>
set
4
OT
RT
>
set
5
OT
RT
>
set
6
OT
RT
>
set
7
OT
RT
>
set
to
15
OT
RT
>
set
"Heating limit: Complete summer economy control"
Setting
None
... °C
"Mixer economy function"
Setting
Without
With
A5:5
A5:0
A5:1 to
A5:15
+ 5 K
+ 4 K
+ 3 K
+ 2 K
+ 1 K
- 1 K
- 9 K
A6:36
A6:5 to
A6:35
A7:0
A7:1
Explanations
Economy function outside temperature: Heating circuit
pump "OFF" when the outside temperature (OT) is
1 K higher than the set room temperature (RT
OT
RT
+ 1 K
>
set
No economy function outside temperature
With economy function outside temperature: Heating
circuit pump "OFF"; see the following table:
Explanations
Extended economy function disabled
Extended economy function enabled: The burner and
heating circuit pump will stop at a variable value, ad-
justable between 5 and 35 °C plus 1 °C. The mixer
closes.
The basis for this is the adjusted outside temperature.
This is based on the actual outside temperature and a
time constant, which takes into account the cooling
down of an average building.
Explanations
Heating circuit pump also "OFF":
If the mixer has been trying to close for some time.
Heating circuit pump "ON":
If the mixer changes to control function
If there is a risk of frost
Parameter level 1
)