Raising The Reduced Room Temperature - Viessmann VITODENS 200-W Installation And Service Instructions Manual

Type b2hb, b2kb, 1.8 to 35 kw wall mounted gas condensing boiler with vitotronic 200, weather-compensated natural gas and lpg version
Table of Contents

Advertisement

Control functions
(cont.)
Temperature profile 4: Parameter F1:4
50
40
30
20
10
1
5
10
Fig. 76
Temperature profile 5: Parameter F1:5
50
40
30
20
10
1
5
10
Fig. 77
Temperature profile 6: Parameter F1:6
60
50
40
30
20
10
1
5
10
Fig. 78
Ends after 21 days
Individual temperature profile for screed drying
An individual temperature profile can be set for screed
drying. See "Commissioning, inspection and mainte-
nance".

Raising the reduced room temperature

During operation at reduced room temperature, the
reduced set room temperature can be automatically
raised subject to the outside temperature. The temper-
ature is raised in accordance with the selected heating
curve, and no higher than the set standard room tem-
perature.
15
20
25
Days
15
20
25
Days
15
20
25
30
Days
30
30
The outside temperature limits for the start and end of
temperature raising can be set in parameters F8 and
F9 in the "Heating circuit" group.
Function description
149