Function Sequence And Possible Faults - Viessmann VITODENS 200-W Installation And Service Instructions Manual

Type b2hb, b2kb, 1.8 to 35 kw wall mounted gas condensing boiler with vitotronic 200, weather-compensated natural gas and lpg version
Table of Contents

Advertisement

Commissioning, inspection, maintenance
Checking the static pressure and supply pressure
Supply pressure (flow pressure)
For natural gas
H
E, E+, M
Below 13 mbar
Below
(1.3 kPa)
17 mbar
(1.7 kPa)
13 to 33 mbar
17 to 33 mbar
(1.3 to
(1.7 to
3.3 kPa)
3.3 kPa)
Above 33 mbar
Above
(3.3 kPa)
33 mbar
(3.3 kPa)

Function sequence and possible faults

Control unit issues a heat
demand
Yes
Fan starts
Yes
Ignition
Yes
Gas train opens
Yes
Ionisation current builds
Symbol
A
36
L, LL, S, K
Lw
Below
Below
18 mbar
16 mbar
(1.8 kPa)
(1.6 kPa)
18 to 33 mbar
16 to 33 mbar
(1.8 to
(1.6 to
3.3 kPa)
3.3 kPa)
Above
Above
33 mbar
33 mbar
(3.3 kPa)
(3.3 kPa)
Display
No
No
Fan starts 4 times for
approx. 50 s, followed by
fault F9
No
Fault 81/EE
No
Fault 80/EE
No
Fault 82/EE
(cont.)
Measures
For LPG
Below
Do not commission the boiler.
25 mbar
Notify your gas supply utility or
(2.5 kPa)
LPG supplier.
25 to
Start the boiler.
57.5 mbar
(2.5 to
5.75 kPa)
Above
Install a separate gas pressure
57.5 mbar
governor upstream of the sys-
(5.75 kPa)
tem. Set the pre-charge pres-
sure to 20 mbar (2.0 kPa) for
natural gas and 50 mbar
(5.0 kPa) for LPG. Notify your
gas supply utility or LPG suppli-
er.
Action
Increase set value and en-
sure heat is drawn off.
Check the fan, fan connect-
ing cables, power to the fan
and fan control.
Check ignition module (con-
trol voltage 230 V across
plugs "X2.1" and "X2.2").
Check the gas supply.
Check the gas train (control
voltage 230 V
gas supply pressure.
Check setting for ionisation
electrode.
Purge the gas line.
); check the