Bleeding The Ptt Unit (Built-In) - Yamaha 250GETO Service Manual

Hide thumbs Also See for 250GETO:
Table of Contents

Advertisement

BRKT
8. Check the fluid level when the rams are
fully extended. If the fluid level is low, add
sufficient fluid, and then repeat step 7.

Bleeding the PTT unit (built-in)

1. Fully tilt the outboard motor up and down
a few times.
NOTE:
Connect the PTT motor leads to the battery
terminals, without installing the power unit. To
connect the PTT motor leads, see "Bleeding
the PTT unit."
2. Let the fluid settle for 5 minutes.
3. Push and hold the PTT switch in the up
position until the outboard motor is fully
tilted up.
4. Support the outboard motor with the tilt
stop lever, and then let the fluid settle for
5 minutes.
w
After tilting up the outboard motor, be
sure to support it with the tilt stop lever.
Otherwise, the outboard motor could sud-
denly lower if the PTT unit should lose
fluid pressure.
7-47
Bracket unit
6S370510
5. Remove the reservoir cap 1, and then
check the fluid level in the reservoir.
NOTE:
If the fluid is at the correct level, the fluid
should overflow out of the filler hole when the
cap 1 is removed.
6. If the fluid is below the correct level, add
fluid of the recommended type.
7. Install the new O-ring reservoir cap, and
then tighten it to the specified torque.
NOTE:
Repeat this procedure until the fluid remains
at the correct level.
Reservoir cap 1:
7 N·m (0.7 kgf·m, 5.2 ft·lb)
1
6S370520
6S35H11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

L250geto

Table of Contents