Mira Vision Dual Installation Manual page 29

Hide thumbs Also See for Vision Dual:
Table of Contents

Advertisement

Push the cut end of the chrome
extension tube into the Ceiling Plate
then slide the extension tube over
the threaded end of the brazed pipe
and up through the hole until the
ceiling plate is secured in the hole
and the ceiling plate is flat against
the ceiling.
Note! If the hole in the ceiling is
oversize use silicone sealant on
the underside of the ceiling plate to
retain it.
Connect brazed pipe in ceiling to
outlet pipe from digital mixing valve
using elbow supplied. Push all parts
together fully and lock elbow onto
pipe using clip supplied.
Connect elbow to digital mixer
valve. Fit an isolating valve between
to enable easy maintenance. (Pipe
and isolating valve not supplied).
Lock pipe to elbow using clip
supplied. Follow manufacturers
guidelines for fitting alternative
push-fit connections and flexible
pipework.
Do not fit deluge head until
after pipework has been fully
flushed through. Refer to section
"Commissioning" in digital mixer
valve Installation guide.
Screw the deluge head onto the
brazed pipe outlet by hand. Note!
Use two suitably sized wrenches to
fully tighten (approximately 1/4 turn).
Slide the extension tube down to
conceal the brazed pipe.
29
Ceiling
Plate
Threaded
end of pipe
Deluge
Head