  • Page 1 InstallatIon & User GUIde These instructions must be left with the user.
  • Page 2: Table Of Contents

    Safety Warnings done so, keep it handy for future reference. Specifications Pressures the mira tabla is a thermostatic mixing valve with a single control knob for on/off and temperature temperatures control. thermostatic shut-down...
  • Page 3: Patents And Design Registration

    Patents and Design Registration saFety WarnInGs Patents: General 2 291 693, 2 340 210, 2 392 225, mira thermostatic mixers are precision engineered 2 421 297 and should give continued safe and controlled euro: 1 672 257 de, Fr, Gb, It, nl, se...
  • Page 4: Specifications

    Connections sPecIFIcatIons • Inlets: 15 mm compression. • Pressures outlet: ½” bsP Flat Face. • • max static Pressure: 10 Bar. standard connections are: hot - left, cold - • right, outlet - bottom. max maintained Pressure: 5 Bar. • •...
  • Page 5: Dimensions

    Dimensions 204 mm 500 mm 123 mm...
  • Page 6: Pack Contents

    1 x shelf Note! do not remove the protective cardboard packaging until installation is complete. 1 x showerhead 1 x mira tabla thermostatic mixing Valve (supplied attached to the backplate and shroud) 1 x clamp bracket 1 x shower hose...
  • Page 7: Installation

    ‘Specifications’. fitted. The inclusion of the Mira DCV-H will increase the required supply pressure typically 1. the mixer must not be installed in an area by 10 kPa (0.1 bar).
  • Page 8: Installing The Thermostatic Mixer

    Installing the Thermostatic Mixer 4. With the backplate assembly positioned centrally in the shower area, mark the positions 1. loosen the control knob grubscrew with the of the holes for the backplate and the pipe 2.5 mm hexagon key (supplied) and pull off centres.
  • Page 9 5. drill the holes for the supply pipes at 153 mm 8. offer up the backplate assembly to the wall and centres. check the position of the fixing holes, for solid walls drill the holes for the backplate with a Important! the holes should be drilled a 6 mm drill and insert the wall plugs (supplied).
  • Page 10 11. Caution! It is essential at this point 17. For user comfort on high pressure systems, that the supply pipework is thoroughly a 12 litre/minute flow regulator (supplied) can flushed through before connection to the be fitted inside the outlet nipple. Make sure mixer. Failure to do so may result in product that the flow regulator is fitted correctly (refer malfunction and will not be covered under the to illustration).
  • Page 11 20. Fit the washer over the rubber sleeve and push 24. assemble the top slide bar support assembly into the top of the shelf hole, (the black surface screw the wall bracket adaptor into the of the shelf must be face down). wall bracket.
  • Page 12 27. remove the slide bar from the shelf. 32. slide the clamp bracket onto the slide bar. 28. Unscrew the locking screw and remove the 33. attach the slide bar onto the slide bar boss and wall bracket and wall bracket adaptor from the wall bracket adaptor, making sure that they are slide bar.
  • Page 13 39. remove the protective cardboard packaging from the shelf. 40. Prior to fixing the hose retaining clip, the underside of the shelf must be cleaned with the cleaning wipe, pay particular attention to the area where the hose retaining clip is to be fitted.
  • Page 14: Commissioning

    7. once the desired maximum blend temperature commIssIonInG has been achieved turn off the mixer by rotating the hub fully clockwise. Maximum Temperature Setting Important! Do not remove the hub. 8. Refit the hub retaining screw. before using the shower, the maximum temperature must be checked to make sure 9.
  • Page 15: Operation

    Mira Tabla is a thermostatic mixing valve which has a single sequential control knob for on/ off and temperature control. the control knob operates anti-clockwise in the following sequence: • • • cold • Warm • maximum Preset temperature...
  • Page 16: User Maintenance

    The hot and cold inlet filters should be checked and cleaned as necessary every 12 months. If you require a mira trained service engineer or Note! The inlet filters must not be removed except agent, refer to section: ‘Customer Services’.
  • Page 17: Cleaning

    Cleaning the chrome plated parts should be cleaned using a mild washing up detergent or soap solution, rinsed and then wiped dry with a soft cloth. Warning! many household cleaners contain abrasive and chemical substances, and should not be used for cleaning plated or plastic fittings. Do not use descalents on this product.
  • Page 18: Spare Parts

    1672.032 component Pack Note! A Cartridge Removal Tool (1672.017) (not illustrated, refer to section: ‘Pack Contents’) is required when replacing the thermostatic 1672.049 seal Pack cartridge (1663.152), available free of charge (contains all seals, not illustrated) from mira customer services.
  • Page 19: Notes

    notes...
  • Page 20: Customer Service

    Our Service Force is available to provide a quality service Damage or defects if the product is taken apart, repaired or at a reasonable cost. You will have the assurance of a Mira modifi ed by any persons not authorised by Mira Showers trained engineer/agent, genuine Mira spare parts and a or our approved agents.