Mira Vision Dual Installation Manual page 18

Hide thumbs Also See for Vision Dual:
Table of Contents

Advertisement

Typical Examples of Poor Plumbing and Installation Practices
DO NOT:
Install the Digital Mixer Valve where it can become frozen
Position the Digital Mixer Valve where maintenance access is poor
Install into a system where the cold water cistern holds less than 230 litres
Install into a system where air locking could occur
Install the user interface in a position where communication with the Digital
Mixer Valve is poor e.g. mixer valve installed under metal bath, in front of
metal cistern, more than the recommended distance away etc.
Install the Digital Mixer Valve onto shared water supplies
Install the Digital Mixer Valve less than 100 mm from the lowest level of water
in the cistern
Fit plastic pipework unless rigidly supported
Less than
230 Litres
Less than
230 Litres
Incorrect
Cold
Take-off
Incorrect
Hot
Take-off
Shared
Supplies
Plastic pipework
not rigidly
supported.
Incorrect
Hot
Take-off
Affected by Metal
Bath / Poor or no
Communication
No
Access
Air-locking
Pipework
Distance Too Far /
Poor or No
Communication
18
Bath Installation
Steel / Cast
Bath
Shower Installation