7 Carefully move the test weights to each
remaining location in the platform.
Result: The alarm should be sounding.
The platform overload indicator light should be
flashing at both the ground and platform
controls.
If the alarm does not sound and
the platform overload indicator
light does not come on with the
test weights in any of the platform
locations, the platform overload
system needs to be calibrated.
See D-5, Calibrate the Platform
Overload System .
There may be an approximate 2
second delay before the overload
indicator light turns on and the
alarm sounds.
8 Test all machine functions from the platform
controls.
Result: All platform control functions should not
operate.
9 Turn the key switch to ground control.
10 Test all machine functions from the ground
controls.
Result: All ground control functions should not
operate.
Machine functions should still
operate with auxiliary power at the
ground controls.
Part No. 106488
Genie Z-45/25 Bi-Energy and Genie Z-45/25J Bi-Energy
Section 3 • Scheduled Maintenance Procedures
CHECKLIST C PROCEDURES
11 Lift the test weights off the platform floor using a
suitable lifting device.
Result: The platform overload indicator light and
alarm should turn off at both the ground and
platform controls.
There may be an approximate 2
second delay before the overload
indicator light and alarm turn off.
12 Test all machine functions from the ground
controls.
Result: All ground control functions should
operate normally.
13 Turn the key switch to platform control.
14 Test all machine functions from the platform
controls.
Result: All platform control functions should
operate.
If the platform overload system is
not operating properly, see D-5,
Calibrate the Platform Overload
System.
3 - 29