Operation Of Band Comparison Function; Examples Of Linear Counter Settings - Panasonic FP7 User Manual

High-speed counter unit
Hide thumbs Also See for FP7:
Table of Contents

Advertisement

7.3 Operation of Band Comparison Function

7.3.1 Examples of Linear counter Settings

 Operation of band comparison match flag
Lower limit
Comparison
match 0 flag
Comparison
match 1 flag
Comparison
match 2 flag
Comparison
match 3 flag
-8,000
 Examples of output pattern settings
Band comparison
Comparison
data
Lower
limit
0
-8,000
1
-4,000
2
+2,000
3
-8,000
4
+4,000
KEY POINTS
The output is off in the areas of the bands in which comparison data is not
set.
Multiple comparison data can be set for the same band.
If the contents of comparison data 0 to 15 are overlapped and the specified
reset conditions are different, the priority of data is in the following order.
(High) 0 > 1 > 2 > 3 > 4 > 5 > 6 > 7 > 8 > 9 > 10 > 11 > 12 > 13 > 14 > 15 (Low)
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Comparison data 0
Comparison data 1
Comparison data 3
-6,000
-4,000
value
Output
pattern
Upper
limit
Set
-6,000
pattern
Set
-2,000
pattern
Set
+4,000
pattern
Set
-4,000
pattern
Set
+8,000
pattern
0
Count value
Comparison data 2
-2,000
+2,000
+4,000
Comparison
Comparison
match 0 flag
match 1 flag
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
Upper limit
Comparison data 4
+6,000
+8,000
Comparison
Comparison
match 2 flag
match 3 flag
ON
ON
OFF
ON
ON
ON
ON
OFF
OFF
ON

Advertisement

Table of Contents
loading