7.3 Operation of Band Comparison Function
7.3.1 Examples of Linear counter Settings
Operation of band comparison match flag
Lower limit
Comparison
match 0 flag
Comparison
match 1 flag
Comparison
match 2 flag
Comparison
match 3 flag
-8,000
Examples of output pattern settings
Band comparison
Comparison
data
Lower
limit
0
-8,000
1
-4,000
2
+2,000
3
-8,000
4
+4,000
KEY POINTS
•
The output is off in the areas of the bands in which comparison data is not
set.
•
Multiple comparison data can be set for the same band.
•
If the contents of comparison data 0 to 15 are overlapped and the specified
reset conditions are different, the priority of data is in the following order.
(High) 0 > 1 > 2 > 3 > 4 > 5 > 6 > 7 > 8 > 9 > 10 > 11 > 12 > 13 > 14 > 15 (Low)
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Comparison data 0
Comparison data 1
Comparison data 3
-6,000
-4,000
value
Output
pattern
Upper
limit
Set
-6,000
pattern
Set
-2,000
pattern
Set
+4,000
pattern
Set
-4,000
pattern
Set
+8,000
pattern
0
Count value
Comparison data 2
-2,000
+2,000
+4,000
Comparison
Comparison
match 0 flag
match 1 flag
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
Upper limit
Comparison data 4
+6,000
+8,000
Comparison
Comparison
match 2 flag
match 3 flag
ON
ON
OFF
ON
ON
ON
ON
OFF
OFF
ON