8.6 Clearing Capture Values Storage Area
8.6.1 Capture Value Clear Request
Clearing capture data
• Capture data can be reset by turning off, on, and off the corresponding bit in the capture
value clear request area.
• The capture 0 register and capture 1 register can be reset individually.
• Data stored in the areas of capture registers and capture register buffers is reset to 0 when
executing the clear request.
8.6.2 Sample Program
Reset program
Example) Program to reset the capture 0 register of CH0 of the high-speed counter unit
installed in the slot No. 1
R0
DF
(
)
KEY POINTS
•
Even if the capture value clear request is executed, the number of
completed capture operations in the buffer area will not be cleared. The
number of completed capture operations will be cleared when the capture
enable request (Y7) or the sampling capture function is activated.
REFERENCE
For details of unit memory (UM) numbers, refer to 11.4 Unit Memory Detailed
Specifications.