7.3.3 Configuration of Band Comparison

 Overview of setting items
• When the current value exists between the lower and upper limits of each comparison data,
the ON or OFF state of each flag is set for each comparison data.
• Multiple comparison match flags can be set for one comparison data.
• Multiple comparison data can be set for the same band.
Upper limit
Lower limit
Upper limit
Lower limit
Setting for Band comparison
 Example of settings by FPWIN GR7
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Comparison data 0
Set pattern
Comparison data 15
Set pattern
Comparison match 0 flag
OR
Comparison match F flag