5.3 Allocation of Reset, Preset and Enable Signals

5.3.1 Reset Input

The following four reset methods are available.
Reset elements
Effective condition
 Type of reset signals
Reset
element
Output Y
relay
Input Z signal
Control 0
signal
Comparison
match flag
 I/O allocation
Signal name
Reset request
Reset enable request
Input Z signal monitor
Control 0 signal monitor
Comparison match flag
(Note 1): The above I/O numbers are those for the slot number 1 and the starting word number 10. The I/O numbers
actually used vary according to the slot number where the unit is installed and the starting word number.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Output Y relay
Input Z signal
Comparison match reset
Control 0 signal
Output Y relay
(Reset enable request)
Setting method
Activates the reset request signal by a user
program.
Allocates the Z-phase input signal to any
reset operation using the configuration
menu.
Allocates the control 0 signal to either reset
operation using the configuration menu.
Positive logic enable operation and reset
operation at rising edge
Negative logic enable operation and reset
operation at trailing edge
Allocates the comparison match flag
operation to "Reset execution" using the
configuration menu.
Effective
condition
ON edge
Level
-
-
-
OR
AND
Reset condition
ON
ON
OFF
OFF
CH0
CH1
Y102
Y112
Y104
Y114
X10A
X12A
X10B
X12B
X110-X11F
X130-X13F
Reset
OR
ON
ON
OFF
OFF
CH2
CH3
Y122
Y132
Y124
Y134
X14A
X16A
X14B
X16B
X150-X15F
X170-X17F

Advertisement