General data, PM240

Feature
Line voltage
Output voltage
Input frequency
Output frequency
Power factor λ
Starting current
Pulse frequency (factory
setting)
Electromagnetic
compatibility
Braking methods
Degree of protection
Operating temperature
Storage temperature
Dirt and contamination
Relative humidity
Environmental requirements Protected against damaging chemical substances according to environmental class 3C2 to
Shock and vibration
Installation altitude
Standards
390
Version
380 V ... 480 V 3-ph. AC ± 10%
0 V 3-ph. AC ... input voltage x 0.95 (max.)
50 Hz ... 60 Hz, ±3 Hz
0 ... 650 Hz, depending on the control mode
0,7 ... 0,85
Less than the input current
4 kHz for 0.37 kW ... 90 kW
2 kHz for 110 kW ... 250 kW
The pulse frequency can be increased in 2 kHz steps. An increase in the pulse frequency
results in a lower output current.
The devices in compliance with EN 61800-3: 2004 are suitable for Category C1 and C2
environments. For details, see the Hardware Installation Manual, Appendix A2
DC braking, compound braking, dynamic braking with integrated braking chopper
IP20 chassis units
LO without derating:
HO without derating:
HO without derating:
LO/HO with derating:
-40 °C ... +70 °C
Protected according to pollution degree 2 to EN 61800-5-1: 2007
< 95% - condensation not permissible
EN 60721-3-3; 1995
Long-term storage in the transport packaging according to Class 1M2 to EN 60721-3-1:
1997
Transport in the transport packaging according to Class 2M3 to EN 60721-3-2: 1997
Vibration during operation according to Class 3M2 to EN 60721-3-3: 1995
without derating:
0.37 kW ... 132 kW
160 kW ... 250 kW
with derating:
all power ratings
UL, cUL, CE, C-tick, SEMI F47
The drive only satisfies the UL requirements when UL-certified fuses are used.
all power ratings
0 °C ... +40 °C
0.37 ... 110 kW
0 °C ... +50 °C
132 ... 200 kW
0 °C ... +40 °C
all power ratings
up to 60 °C
up to 1000 m above sea level
up to 2000 m above sea level
up to 4000 m above sea level
Operating Instructions, 11/2013, FW V4.6.6, A5E02430659B AG
For details, see the
Hardware Installation
Manual.
For details, see the
Hardware
Installation Manual
Inverter with CU230P-2 Control Units

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g120dCu230p-2

Table of Contents