1.6

Range Setting Restrictions

The following combinations cannot be specified within the same unit when setting the
range for each channel using software.
Range
Voltage
+ / - 10 V,
input
1 to 5V
+ / - 100 mV
Current input
Thermocouple input
R.T.D. input
The current input and thermocouple input cannot be used at the same time.
The current input and R.T.D. input cannot be used at the same time.
The current input and +/ - 100mV voltage input cannot be used at same time.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Voltage input
+ / - 10V,
+ / - 100 mV
1 to 5V
A
A
A
A
A
N/A
A
A
A
A
A: Combination available, N/A: Combination not available
Functions and Restrictions
1.6 Range Setting Restrictions
Current in-
Thermocou-
put
put
ple input
ple input
A
A
N/A
A
A
N/A
N/A
A
N/A
A
R.T.D. input
A
A
N/A
A
A