Problem
Oil will not heat (con-
tinued)
Oil heating too slow
Oil overheating
Oil foaming or boiling
over vat
Oil will not drain from vat
Oil leaking through drain
valve
Aug. 2012
Cause
HEATING OF SHORTENING SECTION (Continued)
Drain valve open
Faulty temperature probe
Faulty gas valve
Low gas pressure
Wire(s) loose
Burnt or charred wire
connection
Programming wrong
Faulty PC board
Faulty temperature probe
Faulty gas valve
OIL LEVEL SECTION
Water in oil
Improper or bad oil
Improper filtering
Cold zone (bottom of vats) full
of crumbs
Improper rinsing after cleaning
the fryer
Drain valve clogged with
crumbs
Faulty actuator
Oil channel clogged
Obstruction in drain
Faulty drain valve
Close drain valve
Replace temerature probe
Check gas valve
Have gas pressure checked
Tighten
Replace wire and clean connections
Check Temperature setting in the
program mode
Replacecontrol board if heat
indicator stays on past ready
temperature
Check probe calibration and
replace if temperature is off ± 5
degrees
Check gas calve
At end of a Cook Cycle, drain and
clean vat; add fresh oil
Use recommended oil
Refer to the procedure on filtering
the oil.
Open valve. using cleaning brush,
force crumbs through drain valve
Replace actuator
Access the clean-out plug on the
sides of the unit (see Oil Channel
Clean-out Section)
Remove obstruction
Replace drain valve