"IS POT FILLED" filter
error prompt
"CHECK PAN" prompt
"CHANGE FILTER PAD"
prompt appears
Aug. 2012
DISPLAYED PROMPT SECTION
All oil did not completely return
after a filter cycle
Filter pad clogged
Filter drain pan missing
Filter drain pan not completely
engaged
Filter drain interlock switch not
engaged
Filter pad has not been changed
within a 24hr time period; Main
power switch was turned off during
filter pad change
Drain pan microswitch stuck
1-6
Model LVG-202, 203, 204
Have manager follow prompts
Is JIB full? If not, fill JIB
Replace filter pad/clean pan.
Find pan and install
Adjust filter drain pan position
Check drain microswitch
Replace old filter pad with NEW
filter pad with main power switch
turned on.
*NOTE* 24/7 store replace filter
twice a day.
Check drain microswitch