7-14. SELECTOR
VALVE DRIVE MOTOR
REPLACEMENT
(CONTINUED)
Calibrate Selector Valve
1. Press and release both
2. Press ◄ or ► until you reach 13. "PUMPS & VALVES".
3. Press the INFO button 3 times "SELECTOR VALVE AT HOME".
4. Press the
then √ to confirm.
5. Once calibration has completed check Port 10 to confirm the inner hole is lined with valve body hole.
6. Continue with the reassembly.
May 2013
20. Tighten the bolts with the 5/32 allan wrench.
•DO NOT tighten the coupler at this time
21. Reconnect the power cord to the unit. The selector valve
will run a quick calibration to find the home position.
22. Once calibration is complete, tighten the coupler to the
motors drive tube.
23. With the coupler tightened to the correct specs, ran a
calibration to confirm all ports are properly aligned.
buttons.
Reinstall Continued
24. Install fitting back to selector valve and tighten. Then
tighten the flex line.
25. Install the shield and plate to the selector valve
assembly.
7-11
•DO NOT install the shield at this time
When tightening the coupler, use
the torque specs are as follows:
Top 2= 50 in-lbs
Bottom 2= 10 in-lbs