Henny Penny LVG-202 Service Manual page 52

Open fryer (gas)
Hide thumbs Also See for LVG-202:
Table of Contents

Advertisement

7-14. SELECTOR
VALVE DRIVE MOTOR
REPLACEMENT
(CONTINUED)
May 2013
11. Using a 5/32 allan wrench (recommended T-Handle),
loosen the 4 screws on the coupler that is clamped onto the
drive tube.
12. Lift motor off of selector valve body.
13. Move to the front of the fryer and locate Port 10 on the
selector valve body. This will be the port located in the JIB
area.
14. Using an adjustable wrench, remove the flex line from port
10.
15. Next remove the fitting and set aside. This will allow the
inside valve to be visible.
16. Rotate the valve by hand until the hole is lined up with the
threaded hole on the valve body.
17. Place the new motor onto the selector valve mounting plate.
18. Plug the encoder wire back into the AIF board where it was
previously removed. Place AIF board box cover back into
position.
19. Reconnect the new motor wires
7-10