Problem
Vat is under-filled
Bubbles in oil during
entire filtering process
Filter motor runs but
pumps oil slowly
Filter motor will not run
July 2013
Cause
OIL LEVEL SECTION (Continued)
Locations with RTI, the 3-way
valve is stuck open
Filter pan needs cleaned
JIB is low or empty
JIB oil line is clogged or
collapsed
Quick Disconnect O-ring may
be worn or missing
Filter pan needs cleaned
Filter pan not completely
engaged
Filter pan clogged
Damaged o-ring on filter line
tube on fryer
FILTER MOTOR SECTION
Filter line connections loose
Drain pan o-rings damaged or
missing
Filter paper or pad clogged
Thermal reset button on the rear
of the pump motor is tripped
To prevent burns caused by splash-
ing shortening, turn the unit's
POWER switch to the OFF position
before resetting the filter pump mo-
tor's manual reset
protection device.
1-5
Model LVG-202, 203, 204
Correction
The RTI system can be
disconnected until RTI repairs the
valve
Clean filter pan and change pad
Fill the JIB
Check JIB line
Check JIB Disconnect O-ring
for wear or cracking. Replace if
missing or torn
Clean filter pan and change pad
Make sure filter pan return line
is pushed completely into the
receiver on the fryer
Clean pan and change pad
Change o-ring
Tighten all filter line connections
Install new o-rings
Change filter paper or pad
Allow time for the motor to cool.
Open front door and using at
least a 12 in. (305 mm) Phillip's head
screwdriver, press on the thermal reset
button by prying hard between the
button and the door frame until button
clicks