Henny Penny LVG-202 Service Manual page 8

Open fryer (gas)
Hide thumbs Also See for LVG-202:
Table of Contents

Advertisement

Problem
With power switch in ON position,
the fryer is completely inoperative
(NO POWER)
Oil will not heat but lights
are on
No Heat error "E-22"
Aug. 2012
Cause
POWER SECTION
Open circuit
HEATING OF SHORTENING SECTION
Blown fuse or tripped
Faulty power switch.
Faulty cord and plug
Faulty drain switch
Faulty PC Board
High limit control switch
"E-10"
tripped
1-3
Model LVG-202, 203, 204
Correction
Check to see that unit is plugged in
Check the breaker or fuse at supply
box
Check voltage at wall receptacle
Check MAIN POWERswitch; re-
place if
defective
Check cord and plug
Reset transformer circuit breaker
Reset breaker or replace fuse circuit
breaker at supply box or control panel
Check power switch
Check cord and plug
Check power at receptacle
Check drain switch
Check control panel per maintenance
section and replace as needed
Allow fryer to cool for 15-20
minutes; reset high limit by
pressing down & releasing raised
side of the switch for the vat that is
not operating; a single reset switch
is found behind the door of each
well; if high limit does not reset,
high limit must be replaced

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lvg-203Lvg-204

Table of Contents