1-4. ERROR CODES
DISPLAY
"E-4"
Control board overheating
Oil overheating
"E-5"
Temperature probe open
"E-6A"
Temperature probe shorted checked
"E-6B"
"E-10"
E-10A- tripped above 300F
E-10B- tripped below 300F
E-10C- tripped while cooking
E-10D- tripped <5min. of Auto Filter
E-10F- tripped during filter cycle
E-10M- tripped during melt mode
E-10Y- tripped <5min of "YES" to
"IS THE POT FULL?" prompt
Drain valve open
"E-15"
Left level sensor open
"E-18-A"
Right level sensor open
"E-18-B"
Both level sensors open
"E-18-C"
"E-20-A"
Pressure switch failure/ Wiring
"FAN
problem
SENSOR
STUCK
CLOSED"
Feb. 2013
In the event of a control system failure, the digital display
shows an error message. The message codes are shown in the
DISPLAY column below. A constant tone is heard when an er-
ror code is displayed, and to silence this tone, press any button.
CAUSE
1-7
CORRECTION
Turn switch to OFF position, then turn switch back
to ON; if display shows "E-4", the control board is
getting too hot; check the louvers on each side of
the unit for obstructions
Turn switch to OFF position, then turn switch back
to ON; if display shows "E-5", the heating circuits
and temperature probe should be checked
Turn switch to OFF position, then turn switch back
to ON; if display shows "E-6A", the temperature
probe should be checked
Turn switch to OFF position, then turn switch back
to ON; if display shows "E-6B", temperature probe
should be
Allow fryer to cool for 15-20 minutes; reset high
limit by pressing down & releasing raisedside of
the switch for the vat that is not operating; a single
reset switch is found behind the door of each well;
if high limit does not reset, high limit must be
replaced
Clean and/or close fish vat drain valve; if clean and
closed, have drain switch continuity checked
Turn switch to OFF position, then turn switch back
to ON; If display still indicates a failed sensor,
check the connectors at the control board; check
sensor & replace, if necessory
If fan is not running, have pressure switch
checked; should be open circuit, if no air pressure
If fan is running, wiring error