5-2. SPECIAL PROGRAMMING
(CONTINUED)
Aug. 2012
2nd Language (SP-3)
6. Press ▼ button and "SP-3 2ND LANGUAGE" scrolls in
left display. Use ◄ and ► buttons to set to: ENGLISH;
FRANCAIS; CAN FREN; ESPANOL; PORTUG;
DEUTSHE; SVENSKA; РУССКИИ or -NONE-.
By setting a second language in the controls, 2 languages
can now be easily chosen by pressing
during normal operation.
One language shows in left display and a second language
shows in the right display. Pressing the √ button selects the
language in the displays.
2nd Volume (SP-4)
7. Press ▼ button and "SP-5 2nd VOLUME" shows in
display. If NONE is displayed, this option is off. Push
◄ and ► to turn option on and to set volume from 1-10.
Quick Configuration (SP-5)
8. Press ▼ button and "SP-5 QUICK CONFIG" shows in
display. Use the ◄ and ► buttons to change the menu
selection in the controls to: CHKN+FISH; FF/HBR; CHKN
or EMPTY.
Polish Duration (SP-6)
9. Press ▼ button and "SP-6 POLISH" shows in left
display. Use product buttons
to change polish time, from 5 minutes to a maximum of
10 minutes.
Drain Valve (SP-7)
10. Press ▼ button and "SP-7 DRAIN VALVE" scrolls in the
left display. Use the ◄ and ► buttons to change the right
display to show "NORMAL" or "MANUAL".
NORMAL means drain valves are controlled electronically
and MANUAL means drain valves must be opened by
hand.
5-4