Nominal Heat Input:
(Net)
Nominal Heat Input:
(Gross)
Supply Pressure:
Test Point Pressure:
Injector Size:
This appliance must be installed in accordance with the manufacturer's instructions and the regulations
in force and only used in a suitable ventilated location. Read the instructions fully before installing or
using the appliance.
Technical Data for CE Marked Products
Natural (I2H) = 19,8, kW (67,560 Btu/h)
Natural (I2E) = 19.8 kW (67,560 Btu/h)
Natural (I2E+) = 19.8 kW (67,560 Btu/h)
Natural (I2L) = 19.8 kW (67,560 Btu/h)
Natural (I2HS) = 19.8 kW (67,560 Btu/h)
Liquid Propane (I3P) = 19,8, kW (67,560 Btu/h)
Liquid Propane/Butane (I3B/P) = 19,8, kW (67,560 Btu/h)
Natural (I2H) = 21,98 kW (75,000 Btu/h) (79.13 MJ/h)
Natural (I2E) = 21,98 kW (75,000 Btu/h)
Natural (I2E+) = 21,98 kW (75,000 Btu/h)
Natural (I2L) = 21,98 kW (75,000 Btu/h)
Natural (I2HS) = 21,98 kW (75,000 Btu/h)
Liquid Propane (I3P) = 21,98 kW (75,000 Btu/h) (79.13 MJ/h)
Liquid Propane/Butane (I3B/P) = 21,98 kW (75,000 Btu/h) (79.13 MJ/h)
Natural (I2H) = 20 mbar (2.0 kPa)
Natural (I2E) = 20 mbar
Natural (I2E+) = 20/25 mbar
Natural (I2L) = 25 mbar
Natural (I2HS) = 25 mbar
Liquid Propane (I3P) = 30/37/50 mbar (3.0/3.7/5.0 kPa)
Liquid Propane/Butane (I3B/P) = 30/50 mbar
Natural (I2H) = 8.7 mbar (.87 kPa)
Natural (I2E) = 8,7 mbar
Natural (I2E+) = N/A
Natural (I2L) = 8.7 mbar
Natural (I2HS) = 8.7 mbar
Liquid Propane (I3P) = 25 mbar (2.5 kPa)
Liquid Propane/Butane (I3B/P) = 30/50 mbar (3.0/5.0 kPa)
Natural (I2H) = 2.08 mm
Natural (I2E) = 2.08 mm
Natural (I2E+) = 1.70 mm
Natural (I2L) = 2.30 mm
Natural (I2HS) = 2.30 mm
Liquid Propane/Butane (I3B/P) = 1.30 mm
Liquid Propane (I3P) *30 mbar = 1.18 mm
Liquid Propane (I3P) *50 mbar = 1.04 mm
Noise generated from this equipment is less than 70 dB(A)