Specifications; Environmental Specifications; Mechanical Specifications - HP ProLiant XL270d Gen9 Maintenance And Service Manual

Accelerator tray
Table of Contents

Advertisement

Specifications

Environmental specifications

Specification
Temperature range
2
3
Operating
,
Nonoperating
Relative humidity (noncondensing)
Operating
Nonoperating
1
All temperature ratings shown are for sea level. An altitude derating of 1.0°C per 304.8 m (1.8°F per 1,000 ft) to 3,048
m (10,000 ft) is applicable. No direct sunlight allowed. Maximum rate of change is 20°C per hour (36°F per hour). The
upper limit and rate of change might be limited by the type and number of options installed.
2
If three or more NVIDIA Tesla K80 GPUs, NVIDIA Tesla P4 GPUs, or NVIDIA Tesla P40 GPUs are installed on one
side of the server, the inlet ambient temperature must be maintained at or below 30°C (86°F). For more information,
GPU accelerator population guidelines
see "
3
If three or more NVIDIA Tesla P100 GPUs or NVIDIA Tesla V100 GPUs are installed on one side of the HPE ProLiant
XL270d Gen9 Accelerator Tray, the inlet ambient temperature must be maintained at or below 25°C (77°F). For more
information, see "

Mechanical specifications

Specification
Height
Depth
Width
Weight (maximum)
Weight (minimum)
122
Specifications
1
GPU accelerator population guidelines
Value
8.40 cm (3.31 in)
85.50 cm (33.66 in)
44.50 cm (17.52 in)
26.32 kg (58.02 lb)
19.94 kg (43.96 lb)
Value
10°C to 35°C (50°F to 95°F)
-30°C to 60°C (-22°F to 140°F)
Minimum to be the higher (more moisture) of -12°C
(10.4°F) dew point or 8% relative humidity
Maximum to be 24°C (75.2°F) dew point or 90%
relative humidity
5% to 95%
38.7°C (101.7°F), maximum wet bulb temperature
"
."