Environmental Specifications - HP ProLiant ML30 Gen10 Plus Maintenance And Service Manual

Hide thumbs Also See for ProLiant ML30 Gen10 Plus:
Table of Contents

Advertisement

Item
Item
Cable label
Cable label
1
HDD PWR (PDB)
2
ODD PWR
3
P4
4
LTO PWR
5
P2
6
NHP PWR
7
BP HP PWR
Specifications
Specifications
This chapter lists the technical specifications for the server, including:

Environmental specifications

Mechanical specifications
Power supply specifications
Environmental specifications
Environmental specifications
Specifications
Specifications
Temperature range*
Temperature range*
Operating
Nonoperating
Relative humidity (noncondensing)
Relative humidity (noncondensing)
Operating
Nonoperating
Altitude
Altitude
Operating
Nonoperating
Connection
Connection
Connects to RPS power distribution board
Connects to the optical drive
Connects to the LTO/RDX power extension cable
LTO/RDX power connector
Connects to the LTO/RDX power extension cable
Connects to the SATA-power splitter cable in the 4
LFF non-hot-plug drive configuration
Connects to the 4 LFF / 8 SFF hot-plug drive
backplane
Value
Value
10°C to 35°C (50°F to 95°F)
-30°C to 60°C (-22°F to 140°F)
8% to 90%
28°C (82.4°F) maximum wet bulb temperature, noncondensing
5% to 95%
38.7°C (101.7°F) maximum wet bulb temperature, noncondensing
3050 m (10,000 ft)
This value may be limited by the type and number of options installed.
Maximum allowable altitude change rate is 457 m/min (1,500 ft/min).
9144 m (30,000 ft)
Maximum allowable altitude change rate is 457 m/min (1,500 ft/min).
HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide
160

Advertisement

Table of Contents
loading

Table of Contents