Continued from previous
4. Replace X3. Remove the contactor X312
32
and measure the resistance of the contactor
with the motor cabling between X312:T1-T2.
Contact
Internal error in the thermal sensor of the motor
controller detector.
5. Switch of the wall-mounted power switch. Undo
33
the contactor at X3 on the motor. Use an ohmmeter to
measure the resistance towards the motor. Measure
between 1-2, 1-3, and 2-3. Correct resistance should be:
W4400H W600H W850H, W1100H
cold motor 0,84 ohm 0,68 ohm
hot motor
1,1 ohm 0,9 ohm
Correct resistance
Troubleshoot the cabling between the motor and motor
controller.
Troubleshooting
Interruption
Defective cabling
between motor
controller and motor.
Inspect the cabling and
replace if necessary.
0,48 ohm
0,6 ohm
One of the resistance values is
incorrect
The motor is probably
defective.
32
X12
33
Contactor X, female towards motor
9
7
7
4
1
1
3
2
Measure resistance between pins 1, 2, , 4,
5 and 6.
57
X12
5950
M1
9
6

402 A