To replace the scale unit
• Remove the machine's left-hand rear side panel.
21
• Disconnect the six connectors to the scale unit.
• Take the scale unit off its mounting plate.
• Install the new scale unit, assembly in reverse order of disassembly.
• Check that the dead load selector is set to 1000-1400 kg for W4400H,
2100-2550 kg for W850H, W1100H and 1200-1600 kg for W600H.
• Calibrate the weighing equipment, see "Calibrate the scale" under
"Machine operation".
21