DOOR LOCK
The signal from the "Door locked " switch is
present although there is no signal from the
"Door closed" switch.
This error code can only be generated prior to
programme start.
If the power is on, be very careful when
working on the machine.
Try to restart the machine (i.e. reset the error
code) by pressing START.
If the error returns, troubleshoot as follows:
1. Undo the card connection X5 on I/O card 1, A11
24
Error message returns
25
I/O card A11 probably defective.
Troubleshooting
No error message
Troubleshoot the door lock
actuator and the cabling
for electric or mechanical
short-circuit.
24
X5
25
Switch cam
Microswitch S
Lock plate
45
97
Lock solenoid and
microswitch S4