X-Axis Power Feed Controls (G0802)
Model G0802 is equipped with a power feed unit
for X-axis table movement. Refer to Figure 5 and
the following descriptions to understand the func-
tions of the various components of the power feed
system.
T
Figure 5. Power feed controls.
-6-
U
V
W
X
AA
Y
Z
T.
Power Feed Limit Switch: Stops table
movement when either of the switch side
plungers are pressed by limit stops.
U. Limit Stop (1 of 2): Restricts table move-
ment by its positioning along front of table.
V. Graduated Collar (X-Axis): Displays dis-
tance of X-axis table travel in 0.001" incre-
ments. One full revolution equal to 0.100" of
table travel.
W. Rapid Traverse Button: When pressed,
moves table at full speed when already in
motion.
X. Direction Lever: Selects direction of table
movement. Middle position is neutral.
Y. Speed Dial: Controls speed of table move-
ment. Turning dial clockwise causes table to
move faster.
Note: Feed rates for table travel are extreme-
ly difficult to precisely calculate. We recom-
mend that you combine research and experi-
mentation to find feed rates that best work for
your operations.
Z.
ON/OFF Switch: Turns power feed ON and
OFF.
AA. Circuit Breaker Reset Button: Resets inter-
nal circuit breaker if unit is overloaded and
shuts down.