X200 series. single-phase input 200v class. three-phase input 200v class. three-phase input 400v class.
Table of Contents

Advertisement

B−32
Func.
Code
B021
B221
B022
B222
B023
B223
B028
B228
B029
B030
B031
B050
B051
More user manuals on
Name
R/W
Overload restriction
R/W
operation mode
Overload restriction
operation mode, 2nd
motor
Overload restriction
R/W
level setting
Overload restriction
R/W
level setting, 2nd
motor
Deceleration rate at
R/W
overload restriction
Deceleration rate at
R/W
overload restriction,
2nd motor
Source of overload
R/W Two option codes:
restriction selection
Source of overload
R/W Two option codes:
restriction selection,
2nd motor
Deceleration rate of
R/W Sets the deceleration rate when
frequency pull-in
restart setting
Current level of
R/W Sets the current level of
frequency pull-in
restart setting
Software lock mode
R/W Prevents parameter changes, in
selection
Selection of the non
R/W Two option codes:
stop operation
Non stop operation
R/W Setting of DC bus voltage to start
start voltage setting
ManualsBase.com
List of Holding Registers
Description
Select the operation mode during
overload conditions, three
options, option codes:
00...Disables
01...Enabled for acceleration and
constant speed
02...Enabled for constant speed
only
Sets the level for overload
restriction, between 20% and
150% of the rated current of the
inverter, setting resolution is 1%
of rated current
Sets the deceleration rate when
inverter detects overload, range
is 0.1 to 30.0, resolution 0.1
00...set value of B022
01...[O] input
00...set value of B222
01...[O] input
frequency pull-in restart, range
is 0.1 to 3000.0, resolution 0.1
frequency pull-in restart, range
is 0.2*inverter rated current to
2.0*inverter rated current,
resolution 0.1
four options, option codes:
00...all parameters except B031
are locked when [SFT]
terminal is ON
01...all parameters except B031
and output frequency F001
are locked when [SFT]
terminal is ON
02...all parameters except B031
are locked
03...all parameters except B031
and output frequency F001
are locked
10...High level access including
B031
00...Disabled
01...Enabled
non stop operation. Range is 0.0
to 1000.0
Network Data
Reg.
Range
Res.
10B5h
0, 1, 2
1529h
10B6h
2000 to
0.01%
15000
152Ah
10B7h
1 to 300
0.1 sec
152Bh
10BBh
0, 1
152Ch
1171h
1 to 30000
0.1 sec
1172h
200 to
0.01%
20000
10BCh
0, 1, 2, 3
10C9h
0, 1
10CAh 0 to 10000
0.1 V