Hitachi X200-002SFE/NFU Instruction Manuals page 131

X200 series. single-phase input 200v class. three-phase input 200v class. three-phase input 400v class.
Table of Contents

Advertisement

Low Load Detection Parameters
The
conjunction with the intelligent output
function, when configured. The output
mode parameter (C038) sets the mode of
the detection at which the low load
detection signal [LOC] turns ON. Three
kinds of modes can be selected. The
detection level parameter (C039) is to set
the level of the low load.
This function is for generating an early
warning logic output, without causing
either a trip event or a restriction of the
motor current (those effects are available
on other functions).
Func.
Code
C038
C039
More user manuals on
following
parameters
"C" Function
Name /
SRW Display
Output mode of low load
Three option codes:
detection signal
00...Disabled
01...During acceleration, deceleration
02...During constant speed only
LOC MODE
CRT
Low load detection level
Set the level of low load detection,
range is 0.0 to 2.0*inverter rated
current
LOC LVL
02.60A
ManualsBase.com
work
in
Output
current
C039
0
[LOC]
output
1
0
Description
and constant speed
3−57
t
t
Run
Defaults
Mode
-FE
-FU
Units
Edit
(EU)
(USA)
01
01
INV
INV
A
rated
rated
curr.
curr.

Advertisement

Table of Contents
loading

Table of Contents