Contents Of Display; Note On Display Of Temperatures; Parameter Programming Procedure (Setup) - Smeg UD505DSUK User Manual

Commercial undercounter dishwasher
Table of Contents

Advertisement

Using the buttons
Button
Display temperatures
Boiler and tank
Scroll through Setup
options (2)
Set Short Programme
Set Medium Programme
Set Long Programme
Set P0 (Empty tank)
1) Restores the default parameters, for new settings see point (6.3)
A series of operations can be carried out when the dishwasher is first installed to customise it to the user's requirements.

6.1 Contents of display

The display provides the following information:
Machine off but energized: OFF
Machine on and ready for use: End/P1-P2-OP3
Wash phase: ||||||||||
Programming phase: See parameter programming section
Error message: See error messages section

6.2 Note on display of temperatures

Temperatures shown on the display might not indicate the actual temperature in the tank and/or boiler during heating - wait
about 1' after the heating elements switch off to see the real temperature.

6.3 Parameter programming procedure (setup)

To modify the parameters, proceed as follows starting with the appliance in "OF" status with the door open.
1) Switch the appliance using the On/OF button
2) Press and hold the button
3) Press the pump-out button
4) Modify the parameter by pressing button P1
5) During setup operations, the description and value of the parameter alternate on the display.
6) Select the other parameters for modification in the same way and proceed as described above
7) To exit the setup menu press and hold
without pressing any key; in this way the machine automatically exits the setup menu.
Short press
On/OF
Start Short Programme
Start Medium Programme
Start Long Programme
Peristaltic pumps in Manual
mode to prime pipes
until the display shows "- -" , release and press again.
to scroll through the parameters for modification
until the display shows "OFF", press P2
Pressed for 2"
Pressed for 5"
Start Pump-out
Start P0
Door closed
10
Long press, release, press
again
Door open and machine OFF.
Long press >>> display reads
"- -" >>> release and press
again: Access Setup Menu (1)
Total pump-out (tank+boiler)
Reset to DEFAULT
parameters (1)
Technician user only
or P3
or wait at least 3 minutes