5 SET-UP

 
Set‐up 
During first start‐up, the functions/parameters listed below must be set or adjusted: 
 
 
A series of operations can be carried out when the warewasher is first installed to customise it to the 
user's requirements. To modify the parameters, proceed as follows.  
5.1 Display Contents 
 
The two digits provide the following information:  
 Appliance off but powered up: decimal points on 
 Appliance on: Boiler temperature 
 Washing phase: Tank temperature 
 Pause phase: Boiler temperature 
 Rinse phase: Boiler temperature 
 Programming phase: See parameter programming section 
 Error message: See error messages section  
5.2 Note on display of temperatures  
Both the Boiler and the Tank temperatures provide instantaneous readings of the current value picked 
up by the probe, but due to the thermal inertia of the probe or its seat, wait about 1 minute after the 
heating element power absorption reading to obtain the real temperature.  
 
 The effective temperature in the boiler will be 5 ° C above the set P2 
(example if set to 80 °, in this temperature it is the detachment of the resistors, to see the true 
temperature wait 1 '= approximately 85 ° C);  if rinse temperature needed 70°C, set P2 65°C) 
 
5.3 Parameter programming procedure 
To access the programming menu, proceed as follows:  
1) switch the appliance off with the (On Off) key 
2) Within 6 seconds, press key P1 (SHORT wash) 7 times. Wait for the 6 seconds to pass; at the end 
P0 appears on the display 
3) Use key P1 to select the parameter to be modified 
4) Press the PUMP‐OUT KEY to display the parameter for modification  
5) Modify the parameter by pressing key P1 
6) Confirm the change by pressing the PUMP‐OUT key 
7) Select the other parameters for modification in the same way and proceed as described above 
8) After setting all the appliance parameters, press the On Off key to quit. 